Products list
Professional Multi-Function OTDR MOT-65 with Network tool and cable testing
OTDR
● 5.4 inch IPS touch screen, 1920*1152 resolutions
● 1310/1550/1610 wavelength optional, 26/28/30/32/34dB Dynamic range optional, max test range 150KM*
● Stable laser source, support CW/270/330/1000/2000Hz
● Test fiber’s length, loss, attenuation parameters and event map, locate connection point/ fusion point
● Automatic analysis of various linkers/fusion points, easy analyze of various events
● Save and view the testing curves, support zoom and move curves, view details
● Support saving curves number ≥30000pcs
● Support create testing report, curve trajectory graphs, parameter settings, fiber event information, and fiber link information
● Report saved as EXCEL, PDF, or screenshots format etc
● Optical Loss test, detect the optical or optical components loss value .It is a key basic function for confirming the optic fiber installation condition and fault status. Light source shares with OTDR ports outputs laser light.
● Visual Fault Locator, it Outputs red light for checking continuity of launch fibers or short patch cord. Breaks and bending in fiber can be identified visually.
● Stable Laser Source, it shares OTDR optical port and work on the same working wavelength of OTDR, the output power can be adjustable for different testing applications. With modulated light at 270Hz/330Hz/1 kHz/2kHz, it can be used for fiber identification or continuity check purpose on a live fiber network.
● Optical power meter with five wavelength 1625nm,1550nm, 1490nm, 1310nm,1300nm, 850nm, linear or nonlinear optical power display, both for optical power testing and Fiber link loss relative measurement.
Cable test:
● Improvement cable tester, UTP cable, telephone cable etc sequence and continuity test, save testing report. Support detect the near-end, mid-end and far-end fault point of the RJ45 cable plug
● Upgraded RJ45 cable TDR test, support cable status and length, max test 600m
● Cable tracer, search BNC cable, network cable and telephone cable from the mess cables
● Cable length, BNC cable, network cable, telephone cable, RVV cable, elevator cable, and cat 5/6 cable’s length test. Max measurement for cable’s open is 3KM* (Short circuit length test not supported) *
Other functions
● Tester Play: Tester, android version mobile phone and PC display at the same time
● Network tool, Ping test, IP scan, PPPOE, Port flashing,etc.
● 7.4V 5200mA Li-ion Battery, 2.5 hours charging, normal working time lasts 11 hours
OTDR Technical Specifications |
|||||||
Wavelength (nm) Optional * |
1310/1550 |
1610 |
|||||
Only support detects optical signal |
Support |
N/A |
|||||
Support Active fiber testing |
N/A |
Support |
|||||
Dynamic range(dB)2 Optional* |
28/26 |
30/28 |
32/30 |
34/32 |
28 |
30 |
32 |
Pulse width (ns) |
5,10,20,30,50,80,160,300,500,800,1000,2000,4000,6000,10000,20000 |
||||||
Testing range |
≤150 Km |
||||||
Event blind zone (m)3 |
≤1.6m |
||||||
Attenuation blind zone (m)3 |
≤8m |
||||||
Linearity (dB/dB) |
±0.05 dB/ dB |
||||||
Loss threshold (dB) |
0.05 |
||||||
Loss resolution ratio (dB) |
0.01 |
||||||
Minimum distance resolution |
0.05 |
||||||
Sampling point(K) |
32-128 |
||||||
Distance uncertainty (m) |
±(1 m + 5×10-5× distance + sampling interval) |
||||||
Distance scope (km) |
0.5,1,2,5,10,25,50,100,200 |
||||||
Typical real-time refreshing duration |
1s |
||||||
File format |
SOR standard format/PDF/EXCEL |
||||||
Measurement duration |
5sec, 10sec, 15sec, 30sec, 1min, 2min, and 3min are selectable |
||||||
Storage |
FLASH (EMMC)8G + TF card (NOT Included ) |
||||||
Interface type |
SC-UPC |
||||||
Remarks: 1. The technical specification describes the ensured performance of the instrument when using typical PC model connector to measure, without considering the uncertainty caused by optical fiber refractivity. 2. Dynamic range is the data measured under the condition of the maximum pulse width and 3 minutes of average time. Dynamic range is the data measured under the condition of 200km/20000ns/3min. 3. Measuring conditions of blind zone: reflection event is within 5Km, reflection strength is 45dB. Measured by the minimum pulse width. 4. TF card not included |