Products list
OTDR: MT-8000
● 8 inch retina touch screen, 2048*1536 resolution
● 1310/1550wavelength ,32/30 dB
● Stable laser source, support CW/270/330/1000/2000Hz
● Optical power meter and visual fault locator
● Test fiber’s length, loss, attenuation parameters and event map, locate connection point/ fusion point
● Automatic analysis of various linkers/fusion points, easy analyze of various events
● Save and view the testing curves, support zoom and move curves, view details.
● Support saving curves number ≥30000pcs
● Support create testing report, including curve trajectory graphs, parameter settings, fiber event information, and fiber link information. Report saved as EXCEL, PDF, or screenshots format etc
● Loss test, detect the optical or optical components loss value
OTDR Technical Specifications |
|||||||||
Wavelength (nm) Optional * |
1310/1550 |
1610 |
|||||||
Dynamic range(dB)2 Optional* |
28/26 |
30/28 |
32/30 |
34/34 |
28 |
30 |
32 |
34 |
|
Only support detect optical signal |
Support |
N/A |
|||||||
Support detect optical signal and testing |
N/A |
Support |
|||||||
Pulse width (ns) |
5,10,20,30,50,80,160,300,500,800,1000,2000,4000,6000,10000,20000 |
||||||||
Testing range |
≤150 Km |
||||||||
Event blind zone (m)3 |
≤2m |
||||||||
Attenuation blind zone (m)3 |
≤10m |
||||||||
Linearity (dB/dB) |
±0.05 dB/ dB |
||||||||
Loss threshold (dB) |
0.05 |
||||||||
Loss resolution ratio (dB) |
0.01 |
||||||||
Minimum distance resolution |
0.05 |
||||||||
Sampling point(K) |
32-128 |
||||||||
Distance uncertainty (m) |
±(1 m + 5×10-5× distance + sampling interval) |
||||||||
Distance scope (km) |
0.5,1,2,5,10,25,50,100,200 |
||||||||
Typical real-time refreshing duration |
1s |
||||||||
File format |
SOR standard format/PDF/EXCEL |
||||||||
Measurement duration |
5sec, 10sec, 15sec, 30sec, 1min, 2min, and 3min are selectable |
||||||||
Storage |
FLASH (EMMC)16G + TF card |
||||||||
Interface type |
FC/SC-PC |
||||||||
Remarks: 1. The technical specification describes the ensured performance of the instrument when using typical PC model connector to measure, without considering the uncertainty caused by optical fiber refractivity. 2. Dynamic range is the data measured under the condition of the maximum pulse width and 3 minutes of average time. Dynamic range is the data measured under the condition of 200km/20000ns/3min. 3. Measuring conditions of blind zone: reflection event is within 5Km, reflection strength is 45dB. Measured by the minimum pulse width. |